← All standards & equipment
API

API 560

Fired Heaters for General Refinery Service

Issuing body
API
Latest edition
5th Edition (2016, A1 2020)
Region
USA, Global
Equipment items
3

Scope

Direct-fired heaters used in refining and general process service. Identical to ISO 13705.

Key requirements (10)

  • Fired heaters for refining and petrochemical service.
  • Types: cabin (vertical), box (horizontal tube radiant), cylindrical (vertical or horizontal).
  • Heat flux limits (radiant): typical 30,000 BTU/hr·ft² (95 kW/m²) for crude/vacuum; up to 50,000 for ethane cracking.
  • Tube design temperature: peak film temperature + 25 °F (14 °C) margin typical.
  • Tube life / creep: per API 530 — Larson-Miller parameter.
  • Burner sizing: 1.2 × maximum design heat release.
  • Excess air: 15% for fuel gas, 20% for fuel oil typical at full load.
  • Casing temperature: < 82 °C (180 °F) at design.
  • Flame impingement: tube clearance ≥ 1× tube OD typical.
  • Convection section: extended-surface (finned/studded) tubes; first row typically bare.

Related standards (2)

Applied to 3 equipment items